Pre-charge cable (ASS070400100)
Pre-charge cable (ASS070400100)
£38.51 "Inc. VAT" Add to basket

Pre-charge cable (ASS070400100)

£38.51 "Inc. VAT"

📦 Order before 4:00pm Monday – Thursday for next-day delivery on all in-stock items! 📦

3 in stock

  • 30 days easy returns
  • Order yours before 2.30pm for same day dispatch
Guaranteed Safe Checkout

Pre-charge cable (ASS070400100)
Pre-charge cable (ASS070400100)
£38.51 "Inc. VAT"






    YesNo


    Pre-charge Cable (ASS070400100)

    Description

    The Pre-charge Cable allows internal capacitors of an inverter, inverter/charger, or MPPT to be pre-charged via the DC terminals before connecting the battery. This method ensures that connecting the battery will not result in arcing at the connection point.

    The pre-charge time for a MultiPlus-II 48/5000 when using the Pre-charge Cable is less than a second. Larger systems will take longer to pre-charge. The largest system targeted with the Pre-charge Cable is a 3-unit system with MultiPlus-II or Quattro (4). For larger systems, several Pre-charge Cables can be used in parallel, or individual units can be pre-charged and connected to the battery one at a time.

    Installation

    1. Connect the battery negative to the inverter.
    2. Do not connect the positive battery cable yet.
    3. Connect the Pre-charge Cable between battery and device:
      1. Connect the BAT+ alligator clamp to the positive terminal of the battery.
      2. Connect the second alligator clamp to the positive input terminal of the inverter, inverter/charger, or MPPT. If needed, use a short extension wire to reach the terminal.
    4. Wait for the yellow LED to switch off indicating the pre-charge process is complete (see LED indications below).
    5. After pre-charging, remove the pre-charge cable and immediately complete the positive battery connection.

    LED Indications

    • Red LED: Indicates reverse polarity. The cable is not damaged but must be disconnected and reconnected correctly.
    • Yellow LED: Lights up while pre-charging. Internal capacitors are charging with a current of up to 0.5 A. The LED turns off when pre-charging is complete and the device is at battery voltage.

    Notes

    • If the pre-charge cable is left connected after pre-charging, it will continue to draw a small current.
    • In larger systems with high-capacitance inverters or chargers, this current may remain at the maximum of 0.5 A.
    • We recommend removing the pre-charge cable after pre-charging is complete to avoid unnecessary power drain.

    Technical Specifications

    Parameter Specification
    Maximum voltage range Up to 70V
    Housing dimensions (h × w × d) 15 × 46 × 23 mm
    Cable length Red cable marked “BAT+”: 40 cm with clamp in red
    Yellow cable: 10 cm with clamp in red

    Reviews